Opteon XP40 (R-449A)

Previous 3 / 7 Next

Opteon XP40 (R-449A) Opteon Series  Refrigerant Chemours

Opteon XP40 (R-449A)

Opteon™ XP40

Download Files

Opteon_XP40_SDS.pdf (485.6 KB)

Opteon ™ XP40 (R-449A) 

  • Replaces R-404A / R-507, R-407A / F and R-22

 

Opteon ™ XP40 (R-449A) has zero ozone depletion potential, low global warming potential (GWP), is based on hydrofluorolefin (HFO), ideal for replacement of R-404A / R-507, R fluids -407A / F, and R-22, for both new equipment and Retrofit in existing equipment. Opteon ™ XP40 has a GWP of 1,282, that is, it has a GWP 65% lower compared to R-404A / R-507. 


ASHRAE Classification :  R-449A


Applications 

  • Commercial Refrigeration 
         - Commercial and industrial refrigeration for low and medium temperatures; 
         - Food services (ex: Condensing units); 
         - Refrigerated storage; 
         - Refrigeration chambers, preparation rooms, etc.

  • Chillers 
         - Direct expansion; 
         - New equipment and retrofit of existing equipment


Benefits

  • Low GWP: 65% reduction compared to R-404A / R-507 *

  • 8-12% more energy efficiency than R-404A / R-507

  • Safe and non-flammable **

  • Approved by major component / equipment manufacturers

  • Alternative for R-407 in low and medium temperatures

  • Compatible with existing equipment and lubricants

  • Efficiency beyond CO2

  • Tested extensively by industry with equipment / lubricants / changes in sealing ***

  • May be completed after leak

* Assessment Report 5 (AR5) 
** ASHRAE A1 Safety Rating 
*** Overheating settings may be required


Properties

Opteon ™ XP40

ASHRAE Classification

R-449A

Composition

R-32 / R-125 / R-1234yf / R-134a

Weight in%

24.3 / 24.7 / 25.3 / 25.7

Molecular weight

87.2 lb / lb soft (108.4 g / mole)

Boiling point at 1 atm (101.3 kPa)

-46.0 ° C (-50.7 ° F)

Critical Pressure

655.0 psia (4447 kPa [abs])

Critical Temperature

81.5 ° C (178.7 ° F)

Liquid Density at 70ºF (21.1ºC)

1113.3 kg / m 3 (69.5 ib / ft3 )

Degradation Potential of the Ozone Layer (CFC-11 = 1.0)

0

Global Warming Potential AR5 (CO 2= 1.0)

1282

ASHRAE Security Classification

TO 1

Glide Temperature

~ 4 K (~7 ° R)


Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start