Opteon XP10 (R-513A)

Previous 5 / 7 Next

Opteon XP10 (R-513A) Opteon Series  Refrigerant Chemours

Opteon XP10 (R-513A)

Download Files

Opteon_XP10_SDS.pdf (479.52 KB)

Opteon ™ XP10 (R-513A) 

  • Replaces R-134a in Commercial Refrigeration

 

Opteon ™ XP10 (R-513A) has zero ozone depletion potential, low global warming potential (GWP), is hydrofluorolefin-based (HFO), ideal for R-134a replacement. In addition, Opteon ™ XP10 is an azeotropic refrigerant fluid and ideal for new equipment and retrofit of existing equipment, offers excellent power capacity as well as the R-134a.


ASHRAE Classification :  R-513A
 

Applications 

  • Medium-cascade hybrid systems;

  • Cooling with medium temperature direct expansion for commercial and industrial application;

  • Water condensing chillers, air-conditioning and heat pumps;

  • New equipment / Retrofit option.


Benefits

  • Low GWP: Reduction of 56% 1 in relation to R-134a;

  • Excellent capacity and energy efficiency compatible with R-134a;

  • Performance similar to R-134a, both in Retrofit and in new equipment;

  • Azeotropic with zero temperature glide;

  • Safe and non-flammable (ASHRAE 2 A1);

  • Approved by the major manufacturers of components and equipment;

  • Field tested without equipment / lubricant / seal changes (overheating adjustments may be required);

  • Compatible with existing designs and lubricants in equipment.

 

(1) According to AR5 - Fifth Assessment Report of the Intergovernmental Panel on Climate Change; 
(2) American Association of Heating, Refrigeration and Air-Conditioning Engineers;

 
Properties

Opteon ™ XP10

ASHRAE Classification

R-513A

Composition

R-1234yf / R-134a

Weight in%

56.0 / 44.0

Molecular weight

108.4 g / mole (108.4 lb / lb mole)

Boiling point at 1 atm (101.3 kPa)

-29.2 ° C (-20.6 ° F)

Critical Pressure

546.2 psia (3766 kpa [abs])

Critical Temperature

96.5 ° C (173.7 ° F)

Liquid Density at 70ºF (21.1ºC)

1185.7 kg / m 3 (74.0 ib / ft3 )

Degradation Potential of the Ozone Layer (CFC-11 = 1.0)

0

Global Warming Potential AR5 (CO 2= 1.0)

573

ASHRAE Security Classification

TO 1

Glide Temperature

0K (0 ° R)

 

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Subscribe Newsletter
1
Hello! Thanks for visiting my site. Please press Start button to Contact with Admin :)

Start